Building and Maintaining a House

Climate Zones, Frost Depth, and Design Loads

The numbers a Wisconsin house is designed around: footings below frost or at least 48 inches down, whichever is deeper; roof snow loads of 40 psf in the northern zone and 30 in the south; floor live loads of 40 psf (50 for garages); 20 psf wind; and the energy code's two zones (15 northern counties in Zone 2) with R-49 ceilings, R-20 or R-21 walls, and U-0.35 windows. Why each matters and how a load travels from the roof to the soil.

  • 5 min
  • 6 steps
  • 3 questions
  • Lesson 3 of 111

In this lesson

  1. How loads travel
  2. Frost
  3. Snow and wind
  4. Floors
  5. Energy zones
  6. What to take from this

How loads travel

Every load on a house has to get to the ground. The roof’s snow pushes on rafters, rafters on walls, walls on floors and girders, those on the foundation, the foundation on the footing, and the footing on the soil, whose bearing capacity is measured in pounds per square foot 1. Wisconsin’s code says the same thing as a rule: every dwelling needs a complete load path from where each load starts to the foundation 2. A beam with no post under its end, or a post with no footing under it, breaks the path.

A gravel road in spring thaw, buckled into humps and ruts where frozen ground swelled and is now softening.
Frost heaves on a gravel road during the spring thaw. Freezing water in the soil lifts whatever sits above it, which is why footings go below the frost line. Credit: Stephen N. Flanders · CC BY-SA 4.0 · Source
Four panels: a footing below the frost line at least 48 inches under grade; roof snow loads of 40 psf in Zone 1 (northern two-thirds) and 30 psf in Zone 2 (south); floor live loads of 40 psf for floors and decks, 50 for garages, 20 and 5 for ceilings, and wind of 20 psf or ASCE 7; and energy zones, with the 15 northern counties of Zone 2 listed and a table of ceiling, wall, basement wall, and window requirements.
Frost, snow, floors, and insulation: Wisconsin's design numbers. Credit: StudyCorner diagram after Wis. Admin. Code SPS 321 and 322 · CC BY 4.0 · Source

Frost

Water in the soil expands when it freezes, and freezing soil under a footing lifts it: frost heave. Doors stick, drywall cracks, stoops tilt away from the house. So 2:

  • Footings and foundations, including those for landings and stoops, go below the frost penetration level or at least 48 inches below adjacent grade, whichever is deeper.
  • Footings may never be placed on frozen material. Pouring in winter means protecting the excavation from freezing.

Exceptions 2:

  • Frost-protected shallow foundations, designed to ASCE 32, use insulation around and under the footing to keep the ground below it from freezing, so the footing can be shallower.
  • The part of a foundation directly under a window areaway.
  • Footings on clean bedrock less than 48 inches down, with the soil cleaned off, clay removed from crevices, and water kept from collecting.

The 48-inch minimum applies statewide; where frost goes deeper than that, the deeper line governs.

Quick check

How deep must a Wisconsin house footing be?

Snow and wind

Roofs must carry the snow load from the UDC’s zone map, applied straight down on the roof’s horizontal projection 2:

Snow zone Where Roof snow load
Zone 1 roughly the northern two-thirds 40 psf
Zone 2 the south, below a line running near Pierce, Clark, Wood, Waupaca, Outagamie, and Brown counties 30 psf

A 30 by 40 foot house in Zone 1 must be built to carry 1,200 × 40 = 48,000 pounds of snow on its roof.

Wind: walls and roofs must resist a horizontal and uplift pressure of 20 psf over the surface, or the loads from ASCE 7 2. That’s what hurricane ties, anchor bolts, and wall bracing are for.

Quick check

A new house in Vilas County: which roof snow load and energy zone apply?

Floors

Floors are designed for live loads: people, furniture, and stored things 2:

Component Live load
Floors 40 psf
Decks, balconies, porches 40 psf
Garage floors 50 psf
Ceilings with storage above 20 psf
Ceilings without storage 5 psf

Plus the dead load, the actual weight of the materials. The joist and rafter span tables in SPS 325 Appendix A are built from these numbers, and can be used instead of calculating each member 2. Lumber that isn’t grade-stamped must be designed as No. 3 grade for studs, joists, and rafters 2.

Energy zones

The energy code has its own map. Zone 2 is 15 northern counties: Ashland, Bayfield, Burnett, Douglas, Florence, Forest, Iron, Langlade, Lincoln, Oneida, Price, Sawyer, Taylor, Vilas, and Washburn. Zone 1 is everything else 3. (The snow map’s numbering runs the other way, so a Vilas County house is snow Zone 1 and energy Zone 2.)

The prescriptive insulation table 3:

Component Zone 1 Zone 2
Windows (max U-factor) 0.35 0.35
Ceiling R-49 R-49
Wood frame wall R-20, or R-13 + R-5 sheathing R-21
Floor over unheated space R-30 R-38
Basement wall R-15 continuous or R-19 cavity same

R-38 satisfies the ceiling where its full uncompressed depth runs over the wall plates at the eaves, and a cathedral ceiling too shallow for R-49 may use R-30 over up to 500 square feet 3. Instead of the table, a builder can show the whole house’s heat loss (its total UA) is no more than the table’s, usually with REScheck software 3. Gas furnaces and boilers must be at least 90% AFUE unless a tighter envelope table is met 3.

Frost Depth And Foundations. Mistakes To Watch Out For! Frost depth and the mistakes that cause heaving. Credit: How to Build Your Own Home · YouTube standard license · 8:31 · Source

Playback is optional. If the player is unavailable, open the video at its source.

Quick check

What does the UDC require for a ceiling with an attic above it, under the prescriptive table?

What to take from this

Footings, stoops included, go below frost or 48 inches, whichever is deeper, and never on frozen ground. Roofs carry 40 psf of snow in the northern zone and 30 in the south; floors 40 psf, garages 50; walls and roofs 20 psf of wind. In the energy code, 15 northern counties are Zone 2; both zones need R-49 ceilings and U-0.35 windows, with R-20 (or 13+5) walls in Zone 1 and R-21 in Zone 2. Every load needs a continuous path down to the soil.

Lesson complete

Nice work.

1day streak
0/1today's goal
–correct

Up next · 5 min

Footings and Frost Depth

Next lesson
Sources for this lesson
  1. 1
    Blueprint Reading and Sketching (NAVEDTRA 14040). U.S. Navy, Naval Education and Training Professional Development and Technology Center. 1994. verifiedPublic domain training manual. Scale blocks (e.g., 1/4 inch = 1 foot); construction drawings are mostly orthographic; plans are horizontal views: plot (site) plans with boundaries, contours, and building lines; foundation plans; floor plans with walls, openings, rooms, and utilities; framing plans for joists, studs, and rafters; elevations are vertical views of each side giving heights; sections are vertical cuts, the most important being wall sections from footing to roof; details are larger-scale drawings at doors, windows, and cornices; specifications carry what drawings can't show; loads travel from horizontal members to vertical members to footings to soil, whose bearing capacity is measured in pounds per square foot.
  2. 2
    Wis. Admin. Code ch. SPS 321, Uniform Dwelling Code: Construction Standards. Wisconsin Department of Safety and Professional Services. verifiedDesign loads (SPS 321.02): complete load path to the foundation; live loads 40 psf floors, 50 garage floors, 40 decks and porches, 20 ceilings with storage, 5 without; roof snow loads from the zone map, Zone 1 (north) 40 psf and Zone 2 (south) 30 psf; wind 20 psf horizontal and uplift or ASCE 7-05; span tables in SPS 325 Appendix A. Frost (321.16): footings and foundations, including stoops and landings, below frost penetration or at least 48 inches below grade, whichever is deeper, never on frozen material; exceptions for ASCE 32 frost-protected shallow foundations, areaways, and clean bedrock. Exits (321.03): two first-floor exit doors separated by the greater of 20 feet or a third of the floor's longest diagonal; egress windows at least 20 by 24 inches net clear opening, sill no more than 60 inches above the floor (a platform if over 46); basement sleeping rooms need a second exit. Ceilings at least 7 feet (321.06). Smoke alarms (321.09) in each sleeping room, outside sleeping areas within 21 feet, and on every level, hardwired and interconnected with battery backup.
  3. 3
    Wis. Admin. Code ch. SPS 322, Uniform Dwelling Code: Energy Conservation. Wisconsin Department of Safety and Professional Services. verifiedZone 2 is 15 northern counties (Ashland, Bayfield, Burnett, Douglas, Florence, Forest, Iron, Langlade, Lincoln, Oneida, Price, Sawyer, Taylor, Vilas, Washburn), Zone 1 the rest. Table 322.31-1 prescriptive values: windows U-0.35, skylights U-0.60, ceilings R-49 (R-38 if full height over the plates), frame walls R-20 or 13+5 in Zone 1 and R-21 in Zone 2, floors R-30 (Zone 1) or R-38 (Zone 2), basement walls R-15 continuous or R-19 cavity; or total UA compliance, e.g. with REScheck. Gas furnaces and boilers at least 90% AFUE unless the tighter Table 322.31-4 envelope is used.